description
当前位置: 主页 > 产品 > Schwarzbeck > LISN

SCHWARZBECK V-LISN(CISPR 16-1-2) NNLK 系列

/uploads/allimg/180925/1-1P9251052340-L.png
型号:SCHWARZBECK V-LISN(CISPR 16-1-2) NNLK 系列
品牌:SCHWARZBECK

特色:
资料下载
型号 Topology Impedance Current max. Paths 频率范围

NNLK 8121

V-LISN

(50 µH + 5 Ω) || 50 Ω

4 x 50 (100) A

 4

9kHz - 30MHz

NNLK 8122

V-LISN

(50 µH + 5 Ω) || 50 Ω

2 x 50 A

 2

9kHz - 30MHz

NNLK 8129

V-LISN

50 µH || 50 Ω

4 x 200 (300) A

 4

(9KHz)150KHz-30MHz

NNLK 8129-2 HV

V-LISN

50 µH || 50 Ω

2 x 200 (300) A

2

(9KHz)150KHz-30MHz

NNLK 8130

V-LISN

50 µH || 50 Ω

4 x 400 (500) A

 4

(9 kHz) 150 kHz - 30 MHz

NNLK 8140

V-LISN

50 µH || 50 Ω

1 x 800 (1000) A

single

(9 kHz) 150 kHz - 30 MHz


NNLK 8121 - Line Impedance Stabilisation Network

 

 

  • Schwarzbeck NNLK 8121 V-LISN
  • Schwarzbeck NNLK8121 V-LISN

  
 

  Topology: V-LISN
  Frequency Range: 9 kHz - 30 MHz
  Impedance simulation: (50 µH+5 Ω) || 50 Ω
  Max. Voltage: 250 VAC 50/60 Hz
400 VDC
   Max. Current:  4 x 50 (100*) A 
  Mains terminals: 4 wing terminals
  Terminals for E.u.T.: 4 wing terminals
     
  Length: 480 mm
  Width: 450 mm
  Height: 370 mm
 

Weight:

33 kg
     
  Standard: CISPR 16-1-2

 

 * For continuously 100 A add the options cont. high current and cooling fans!

pdficon small Datasheet NNLK 8121

pdficon small Data

 

Options:

 Opt. RC:

Option RC for LISN: Remote Control with built in power supply. LISN can be controlled by R&S or Schwarzbeck code, including remote control cable for your receiver type (Please specify your receiver type!). LISN can be selected from the R&S receiver menu or in the EMC32 software like an R&S LISN. No programming of the user interface necessary. Functions: path selection and PE grounded or via choke.

 

pdficon small NNLK 8121 Opt. RC

 

 Opt. Hochstrom:

Option: cont. high current, additional terminals to bypass the 250 µH prefilter-chokes, provides less voltage drop and less heating.

 

pdficon small NNLK 8121 Option Hochstrom

 

 Opt. 400/700 V:

 Option: 400/700 V Voltage to ground / Voltage between lines

 

 Opt. Lüfter:

 Option: Cooling Fans

 

Opt. TC:

The temperature monitor modul which is optional available for the NNLK LISN warns the user optical and acoustical when the temperature gets too high. It controls the fans of the LISN temperature-dependent, too and thus prevents overheating. If a critical temperature is reached the temperature control modul indicates this optically and acoustically.

 

pdficon small NNLK 8121 Opt. TC


 


 

NNLK 8122 - Line Impedance Stabilisation Network

 

 

  • NNLK 8122
  • NNLK 8122_1
  • NNLK 8122_2

  
 

  Topology: V-LISN
  Frequency Range: 9 kHz - 30 MHz
  Pre-filter choke: 250 µH
  Impedance simulation: 50 Ω || (50 µH + 5 Ω)
  Max. Voltage: 1000 VCD 
  750 VAC 50/60 Hz
   Max. Current:  50 A
 

 

 
  Length: 550 mm
  Width: 450 mm
  Height 290 mm
  Weight: 22.2 kg
     
     
  Standard: CISPR 16-1-2

 

pdficon small Datasheet NNLK 8122


 


 

NNLK 8129 - Line Impedance Stabilisation Network

 

 

  • Schwarzbeck NNLK 8129
  • Schwarzbeck NNLK 8129_back

  
 

  Topology: V-LISN
  Frequency Range: (9 kHz) 150 kHz - 30 MHz
  Impedance simulation: 50 µH || 50 Ω
  Max. Voltage:

250 VAC 50/60 Hz
400 VDC

   Max. Current:  4 x 200 (300) A 
  Mains terminals: 4 wing terminals
  Terminals for E.u.T.: 4 wing terminals
     
  Length: 604 mm
  Width: 446 mm
  Height: 355 mm
 

Weight:

30.5 kg
     
  Standard: CISPR 16-1-2

 

pdficon small Datasheet NNLK 8129

pdficon small Data

 

Optionen:

Opt. RC

Option RC for LISN: Remote Control with built in power supply. LISN can be controlled by R&S or Schwarzbeck code, including remote control cable for your receiver type (Please specify your receiver type!). LISN can be selected from the R&S receiver menu or in the EMC32 software like an R&S LISN. No programming of the user interface necessary. Functions: path selection and PE grounded or via choke.

 

pdficon small NNLK 8129 Opt. RC

 

Opt.400/700 V:

400/700 V Voltage to ground / Voltage between lines


Opt.Lüfter:

Cooling Fans

 

Opt. TC

The temperature monitor modul which is optional available for the NNLK LISN warns the user optical and acoustical when the temperature gets too high. It controls the fans of the LISN temperature-dependent, too and thus prevents overheating. If a critical temperature is reached the temperature control modul indicates this optically and acoustically.

 

pdficon small NNLK 8129 Opt. TC


 


 

NNLK 8129-2 HV - Line Impedance Stabilisation Network

 NEW

 

  • NNLK 8129-2 HV
  • NNLK 8129-2 HV_R

  
 

  Topology: V-LISN
  Frequency Range: (9 kHz) 150 kHz - 30 MHz
  Impedance simulation: 50 µH || 50 Ω
  Max. Voltage:

1000 VAC 50/60 Hz
1000 VDC

   Max. Current:  2 x 200 (300) A 
  Mains terminals: Wing terminals 12 mm, removable
  Terminals for E.u.T.: Wing terminals 12 mm, removable
     
  Length: 520 mm
  Width: 445 mm
  Height: 385 mm
 

Weight:

~22 kg
     
  Standard: CISPR 16-1-2

 

pdficon small Datasheet NNLK 8129-2 HV

 

 

Optionen:

Opt. RC

Option RC for LISN: Remote Control with built in power supply. LISN can be controlled by R&S or Schwarzbeck code, including remote control cable for your receiver type (Please specify your receiver type!). LISN can be selected from the R&S receiver menu or in the EMC32 software like an R&S LISN. No programming of the user interface necessary. Functions: path selection and PE grounded or via choke.

 

pdficon small NNLK 8129-2 HV Opt. RC

 

Opt. TC

The temperature monitor modul which is optional available for the NNLK LISN warns the user optical and acoustical when the temperature gets too high. It controls the fans of the LISN temperature-dependent, too and thus prevents overheating. If a critical temperature is reached the temperature control modul indicates this optically and acoustically.

 

pdficon small NNLK 8129-2 HV Opt. TC


 


 

NNLK 8130 - Line Impedance Stabilisation Network

 

 

  • NNKL8130
  • NNKL_8130

  
 

  Topology: V-LISN
  Frequency Range: (9 kHz) 150 kHz - 30 MHz
  Impedance simulation: 50 µH || 50 Ω
  Max. Voltage: 250 VAC 50/60 Hz 
400 VDC
   Max. Current:  4 x 400 A  (with fans ON)
  Mains terminals: 4 wing terminals
  Terminals for E.u.T.: 4 wing terminals
     
  Length: 738 mm
  Width: 448 mm
  Height: 473 mm
 

Weight:

~55 kg
     
  Standard: CISPR 16-1-2

 

pdficon small Datasheet NNLK 8130

pdficon small Data

 

Optionen:

Opt. RC

Option RC for LISN: Remote Control with built in power supply. LISN can be controlled by R&S or Schwarzbeck code, including remote control cable for your receiver type (Please specify your receiver type!). LISN can be selected from the R&S receiver menu or in the EMC32 software like an R&S LISN. No programming of the user interface necessary. Functions: path selection and PE grounded or via choke.

 

pdficon small NNLK 8130 Opt. RC

 

Opt.400/700 V:

400/630 V Stern-/Dreieckspannung

 

Opt. TC

The temperature monitor modul which is optional available for the NNLK LISN warns the user optical and acoustical when the temperature gets too high. It controls the fans of the LISN temperature-dependent, too and thus prevents overheating. If a critical temperature is reached the temperature control modul indicates this optically and acoustically.

 

pdficon small NNLK 8130 Opt. TC


 


 

NNLK 8140 - V-LISN

 

 

  • Schwarzbeck NNLK 8140 V-LISN
  • Schwarzbeck NNLK8140 V-LISN

  
 

  Topology: Single path V-LISN
  Frequency range: (9 kHz) 150 kHz - 30 MHz
  Impedance: 50 µH || 50 Ω (+/- 20 %)
  max. voltage (DC): 1000 VDC
  

max. voltage
(50/60 Hz AC) :

1000 VAC
 

max. voltage
(400 Hz AC):

500 VAC
  max. const. current: 800 A
  max. current (limited time): 1000 A
  Mains connectiors: 2 wing terminals M16x1.5 removable
  EuT connectors: 2 wing terminals M16x1.5 removable
     
  Length: 770 mm
  Width: 445 mm
  Hight: 505 mm
  Weight: 46 kg
     
  Standard: CISPR 16-1-2

 

pdficon small Datasheet NNLK 8140

 

Opt. TC

The temperature monitor modul which is optional available for the NNLK LISN warns the user optical and acoustical when the temperature gets too high. It controls the fans of the LISN temperature-dependent, too and thus prevents overheating. If a critical temperature is reached the temperature control modul indicates this optically and acoustically.

 

pdficon small NNLK 8121 Opt. TC